14700101 Failure to Query the System Parameter
Error Message
System parameter can not be found.
Description
This error code is reported when the parameter does not exist in the workspace or no key has been set for the parameter.
Possible Causes
The parameter is not set or fails to be set.
Solution
Set the parameter correctly.
14700102 Invalid System Parameter Value
Error Message
System parameter value is invalid.
Description
This error code is reported when the value of the system parameter is invalid.
Possible Causes
The value of the system parameter is empty, is out of range, or contains special characters, for example, const.param.xxx.
Solution
Set the value to a valid string.
14700103 Permission Denial for the Operation on the System Permission
Error Message
System permission operation permission denied.
Description
This error code is reported when the system parameter does not have the discretionary access control (DAC) or mandatory access control (MAC) permission.
Possible Causes
The DAC or MAC permission is not configured.
Solution
Add the DAC or MAC permission as needed.
14700104 Internal System Error, Including Out of Memory and Deadlock
Error Message
System internal error including out of memory, deadlock etc.
Description
This error code is reported when the attempt to modify the const attribute settings, the socket connection, or the memory copy fails.
Possible Causes
The socket connection is abnormal, or the node fails to be added or obtained.
Solution
- Analyze the memory usage of the entire process and eliminate memory leak.